GREENPOWER Volvo Diesel Power generator 100kVA 80kW Soundproof canopy Automatic starting  




greenpower

Greenpower Equipped with stable framework, Green Power electrical panel, voltmeter, frequency meter, ampere meter, hour meter, key switch and indicator panel for the oil, battery charging and low fuel level. As an option, we also produce the silenced version.

Specification

  • Prime running Power(PRP) 100kVA 80kW and Emergency standby Power(ESP) 110kVA 88kW at 230/400v @50hz 1500rpm
  • High quality and reliable 4 cylinder, Volvo Penta diesel engine
  • Ideal for business applications
  • Automatic changeover (ATS), Maintenance Free Batteries and Trickle Charger Included
  • Brushless alternator with AVR provides stable output
  • High temperature and low oil, water and fuel protection to protect against engine damage
  • Easy to use Digital Controller with Auto and Manual Start Options

» Click Here to view the Engine Datasheet

» Click here to see Datasheet

Technical Data 
Generator engine  VOLVO TAD 531GE
Type 4 cycle, water-cooled, diesel engine
No of cylinders 4
Cylinders arrangement In-line
Displacement 4.76 Liters
Bore x Stroke 108 x 130 mm
Prime running Power(PRP) 100 kVA/80 kW
Emergency standby Power(ESP) 109KVA/87.2 kW
Speed 1500 rpm
Motor power 117.4 hp/87.6kW
75% consumption 18.3 (l / h)
Rated current 160 Amp
Rated voltage 400V/230V
Landuse type of unit Low noise, Automation type
Dimension (LxBxH) 2830 x 1100 x 2090 mm
Weight 1700 kg
Moving 4760cc
Noise level 69dB (A)
Frequency 50Hz
Gross engine power
88 kWb
 
General Specification for silent Generator :
  • Modular Design
  • Anti Corrosion powder coated
  • Insulated with acoustic foam lining
  • Central lifting ring, exhaust pipe can be removed, which is easy to transport
  • Lockable doors with key
  • Protective mesh for rotating parts
  • Exterior emergency stop push button
  • Thermally insulated engine exhaust system
  • Doors fitted on each side
  • Panel observing window
  • Access to the radiator fill or cap
  • 20', 30' or 40' conopy is optional
  • Color is optional
  • Fuel gauge or lube drain valve is optional
  • Normal or super soundproof canopy is optional
  • Base frame fuel tank or profile fuel tank is optional
  • The muffler fixed position depend on the output power of the Gen-set 

Silent Generator set Canopy :

  • Specially treated steel sheet
  • Stainless steel locks
  • Control panel viewing window for monitoring the status of the generator set
  • Good ventilation system and anti-heat radiation saturation
  • Effective anti-vibration devices to ensure generator driven steadily
  • Super silent materials inside to ensure the noise lower than 68 dB 7 meters away
  • Emergency stop button mounted outside
  • Side lockable door easy for maintenance and installation
  • Lube oil and cooling water drain pipe to the exterior of the canopy
  • Fuel tank built with level indicator
 Standard equipment  Other configurations
  • Automatic fuse magnetothermal
  • Autostart
  • Automatic Power switch ATS
  • Automatic power switch and phase-out
  • Circuit breakers
  • Voltage meter
  • Frequency meter
  • Ampere meter
  • Hour meter
  • Emergency stop button
  • Safety device in the engine for:
    • high water temperature
    • low oil pressure
    • low fuel level 
    • battery charging error
  • Models with different voltage
  • 60 Hz version
   
 Accessories
 
  •  Mobile device on wheels 
  •  Type-approved trailer 
  •   Parallel operation 
  •  Fuse type 
  •  Ground fault switch 
  •  Extraction point with current transformers at zero point 
  •  Radiostatic protection VDE 0875 curve N 
  •  Electronic speed control 
  •  Oil heater 
  •  Engine heater 
  •  Oil pump 
  •  Automatic tanker from external tank 
  •  Protective frame with lift hook 
  •  Container unit 
  •  Alternator voltage / frequency generator 
  •  Fuel tank deployment 
  •  Fuel level 
  •  Alarm on all internet connection.
  •  GSM alarm monitoring
  •  Capable soundproofing 70dB down to 55dB
  •  Remote control
  •  Environmental Class STAGE III
  •  Disconnect 1-phase or 3-phase, respectively
  •  UPS system battery backup 1-phase and 3-phase

Standard Genset Specifications
Engine

  • Volvo heavy duty diesel engine
  • Four cylinder equipped with Water cooling
  • Electronic governor control system
  • Replaceable wet type cylinder liners
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Volvo Engine Manual

Alternator

  • Brushless, single bearing system, 4 poles
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP 22
  • Self-exciting and self-regulating
  • Screen protected and drip proof
  • Close voltage regulation
Greenpower AB reserves the right to make any errors or changes in specifications. © Copyright / Greenpower AB.
  • GREENPOWER  Volvo Diesel Power generator 100kVA 80kW Soundproof canopy Automatic starting
    Art. nr.
    GP100VOSAS
    GREENPOWER Volvo Diesel Power generator 100kVA 80kW Soundproof canopy Automatic starting
    Write down the required equipment for quotation :
For more information contact us at
0431-222 90
  Contact   Print